unità condensante semiermetica BT da 10.00HP P-FL051Z2012-44
volt 400/3/50 componenti: ricevitore di liquido, antivibrante in mandata, pressostato di sicurezza di alta e bassa, filtro e spia.
unità condensante semiermetica BT 10.00HP P-FL051Z2012-44 con compressore Frascold, gas: R452A/R448A/R449/R404A. |
|||||||||||||||||||
m³ | codice | power | condensatore | Ø tubi in mm | R452A performance in W Tamb amb. 32°C | dimensioni in cm | optional | ||||||||||||
cella | unità | comp. | hp | mc/h | watt | A | n° e Ø vent. | volt vent. | D mm | S mm | -40 | -35 | -30 | -25 | -20 | A | B | h | carena |
192-235 | P-FL051Z2012 | S10-52Y | 10.0 | 51.50 | 10294 | 18.96 | 2X45cm | 230/1/50 | 16 | 35 | 6749 | 8533 | 10591 | 12940 | 15588 | 132 | 87 | 86 | 2X450 |
R448/449A performance in W Tamb amb. 32°C | |||||||||||||||||||
156-204 | 4339 | 6305 | 8594 | 11225 | 14202 | ||||||||||||||
R404A performance in W Tamb amb. 32°C | |||||||||||||||||||
208-254 | 6906 | 9104 | 11440 | 13958 | 16688 | ||||||||||||||
l'impianto contiene gas fluorurati a effetto serra come il R404A e quindi devi rispettare il regolamento UE n.517/2014 +info |
di seguito troverai gli evaporatori consigliati per questa unità. gli abbinamenti, validi per la conservazione ma non per l'abbattimento, sono stati fatti considerando la temperatura ambiente di 32° e quella interna alla cella di 0°. |
|||
|
|
|
|
di seguito trovi le celle freezer BT con la cubatura adatta per questo impianto, dimensioni: |
||||||||||
cella BT 481X1011cm h388cm 154.85m³ |
richiedi un preventivo |
cella BT 600X1011cm h334cm 167.75m³ cella BT 600X1459cm h334cm 244.35m³ |
||||||||
|
ATTENZIONE! per la vendita online di impianti e parti di impianto frigorifero abbiamo pubblicato una selezione che rappresenta solo in parte l'enorme offerta che abbiamo: chiller, Scroll, scambiatori, condensatori, evaporatori a parete, ecc. ma possiamo fornire qualunque tipo di allestimento o parte di esso. per un preventivo ad hoc. invia una richiesta specifica. disponimo anche di molto materiale usato che trovi nella categoria "gruppi frigo, evaporatori e accessori TN e BT usati".
m³ | codici | power | condensatore | Ø tubi in mm | performance in W Te-30°C - Tamb 32°C | dimensioni in cm | optional | PED | ||||||||||
cella | unità | comp. | hp | m³/h | watt | A | n° e Ø vent. | volt vent. | D mm | S mm | R404A | R448/449A | R452A | A | B | h | carenatura | categ. |
8-9.0 8.5-10 14-17 15-19 21-25 22-27 40-46 46-50 52-55 57-65 60-65 72-78 84-99 102-122 128-155 156-208 179-224 210-245 255-287 323-343 399-430 485-522 |
P-FL005Z2012 P-FL006Z2012 P-FL007Z2012 P-FL008Z2012 P-FL009Z2012 P-FL010Z2012 P-FL013Z2012 P-FL015Z2012 P-FL016Z2012 P-FL018Z2012 P-FL021Z2012 P-FL025Z2012 P-FL028Z2012 P-FL033Z2012 P-FL042Z2012 P-FL051Z2012 P-FL056Z2012 P-FL059Z2012 P-FL071Z2012 P-FL084Z2012 P-FL106Z2012 P-FL126Z2012 |
A0.5-5Y A0.7-6Y A1-7Y A1.5-8Y A1.5-9Y A1.5-10Y D2-13Y D2-15Y D3-16Y D3-18Y Q4-21Y Q4-25Y Q5-28Y Q5-33Y S8-42Y S10-52Y S15-56Y V15-59Y V15-71Y V20-84Y Z25-106Y Z30-126Y |
1/2 3/4 1.00 1.50 1.50 1.50 2.00 2.00 3.00 3.00 4.00 4.00 5.00 5.00 8.00 10.00 15.00 15.00 15.00 20.00 25.00 30.00 |
4.93 5.47 6.91 7.65 8.96 9.84 13.84 15.36 16.39 17.93 21.00 24.69 27.88 32.66 41.32 51.50 56.00 58.48 70.77 83.81 106.16 125.72 |
994 1096 1435 1551 1846 2064 2491 2813 3161 3343 3822 4449 5542 6852 7951 10294 10884 11729 14186 16811 21081 23219 |
2.50 2.60 3.24 3.84 4.43 4.67 6.09 6.44 7.59 7.78 8.12 8.43 10.79 12.58 15.19 18.96 23.69 23.73 25.27 31.66 38.33 39.82 |
2X30cm 2X30cm 2X30cm 2X30cm 2X30cm 2X30cm 2X35cm 2X35cm 2X35cm 2X35cm 2X35cm 2X35cm 2X40cm 2X45cm 2X45cm 2X45cm 2X45cm 2X56cm 2X56cm 2X56cm 2X63cm 2X63cm |
230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 400/2/50 400/2/50 400/2/50 400/2/50 400/2/50 |
10 10 10 10 10 10 12 12 12 12 12 12 16 16 16 16 16 22 22 22 22 22 |
16 16 16 16 16 16 22 22 28 28 28 28 35 35 35 35 42 42 42 42 54 54 |
845 960 1341 1521 1760 1915 2795 2981 3331 3921 3909 4572 5742 6985 8807 11440 12320 13240 15194 17827 21501 25305 |
689 820 1102 1270 1487 1492 2391 2812 3097 3404 3658 4361 4911 5868 7327 8594 9825 11345 13541 16839 20222 25606 |
785 890 1243 1407 1627 1773 - - - - 3616 4223 5312 6466 8152 10591 11402 12265 14060 - 19938 23506 |
80 80 80 80 80 80 93 93 93 93 93 93 111 111 111 132 132 165 165 165 218 218 |
56 56 56 56 56 56 68 68 68 68 68 68 79 79 79 87 87 105 105 105 117 117 |
42 42 42 42 42 42 46 46 46 46 46 61 63 73 73 86 86 88 88 88 121 121 |
2X300 " " " " " 2X350 " " " " " 2X400 2X450 " " " X X X X X |
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 2 2 2 2 2 2 2 |
l'impianto conterrà gas fluorurati a effetto serra come il R404A e quindi devi rispettare il regolamento UE n.517/2014 +info |